Model for electrical qualification - Plumber / Heating engineer

Portable model for use in electrical hazard certification (B0 / BE / BS) in a residential environment.
The educational content is based on the rules set out in the French standard for electrical hazard prevention.

Educational objectives
• Apply knowledge, rules, and methods for electrical hazard certification
• Perform practical work related to B0/BE/BS electrical certification
• Perform electrical equipment lockout operations (air conditioning unit, electric boiler, outlet)
• Take measurement readings using a multimeter (not provided)

Selected reference HABILIT3
Quantity

Selected reference HABILIT3
Selected reference HABILIT3

Practical work provided
• Review of electrical certification
• Locking out a circuit breaker and a fuse
• Completing the lockout and certification documents
• Verifying the proper use of PPE
• Measuring voltage and testing continuity with a multimeter (not provided)

Examples of possible interventions
• Powering down and locking out
• Replacing a low-voltage fuse
• Connecting the terminal block of an electric boiler
• Removing and replacing a power outlet
• Connecting the terminal block of an indoor air conditioner unit
• Connecting the terminal block of an outdoor air conditioner unit
• Resetting a protective device on instruction

Composition
• 1 modular panel containing the various electrical protection devices
• 1 socket module for powering the model with 230VAC / 50Hz 2P+E (cable provided)
• 1 40A-30mA residential-type residual current device (RCD)
• 1 electric hot water tank circuit consisting of a 16A circuit breaker for the power circuit and a 2A circuit breaker for the control circuit.
The control circuit consists of a weekly timer that controls the coil of the modular contactor. The power circuit consists of a modulating contactor and a silk-screened interface representing a hot water tank with a connection terminal block and a power indicator light.
• 1 socket circuit consisting of a 16A fuse holder, a flush-mounting box, and a socket.
• 1 air conditioning unit circuit consisting of a junction box and two screen-printed interfaces with a connection terminal block and a power indicator light.
One represents the indoor unit and the other the outdoor unit. The electrical circuit is protected by a 20A circuit breaker.
• 1 lockout device + 1 padlock + 1 lockout indicator sticker ("EQUIPMENT LOCKED - DO NOT OPERATE")
• 1 lockout certificate and work completion notice booklet